Choosing NIR Analysis: Samples, Parameters and Calibration

NIR relates sample spectra to a calibration model. Start with the material and required parameters, then check calibration support and comparison against a reference laboratory.

Match the method to your sample

X-NIR: handheld analysis

Principal materials address grain and forage. Measurements near the sampling location still require checks on calibration, sample condition and result-acceptance criteria.

View instruments · X-NIR: handheld analysis

Palm QC: evaluate the application first

The reviewed public calibration lists do not establish standard palm-matrix support on either model. Separate fruit, kernel, kernel meal and CPO; confirm the matrix, parameter, range and validation before an application quotation.

Instrument options

View the related catalog
AgriNIR 4.0
Dinamica Generale

AgriNIR 4.0

NIR analysis

Carry AgriNIR 4.0 to the sample, then move the same EvoNIR sensor to a compatible forage harvester or feed mixer. Match the mounting kit to your machine and the calibration to your material.

View details
X-NIR
Dinamica Generale

X-NIR

NIR analysis

Screen silage or grain at intake with the handheld X-NIR. Before routine use, check that the calibration fits your material and agrees with your lab’s reference results.

View details

Related reading

Official resources (5)

All resources

Questions to ask before choosing an instrument

Can the sensor be used on a processing line?

Dinamica Generale documents fixed EvoNIR installations in alfalfa dryers and grain elevators, among other applications. For palm mills, identify the measurement point, material, parameter range and reference method. Integration and calibration suitability need checking for each line.

Does calibration for one material cover every palm sample?

No. Suitability for one matrix does not establish suitability for another. Do not assume that FFA, iodine value or DOBI are available; request evidence for the model, matrix and parameter.

How should time savings, costs or yield improvements be evaluated?

After confirming technical suitability, compare a pilot with the current workflow using representative samples. Include full QC turnaround, confirmation tests and operating costs. Trace yield effects through process actions; an analyzer alone does not guarantee improvement.

What should you tell AE?

  • Sample identity, process origin, target parameters and variability.
  • Reference laboratory method, comparison data and acceptance criteria.
  • Sample count, target decision time and current QC workflow costs.