AgriNIR 4.0
Dinamica Generale · NIR analysis

AgriNIR 4.0

Carry AgriNIR 4.0 to the sample, then move the same EvoNIR sensor to a compatible forage harvester or feed mixer. Match the mounting kit to your machine and the calibration to your material.

Download information sheet (Indonesian) AE · PDF · 124 kB
Availability
Confirm availability with AE
Discuss this product

If you need installation or training, ask for it to be itemized in your quote.

Technical specifications

Measurement configuration
Portable AgriNIR 4.0 with automatic sample rotation. NIReverse enables the EvoNIR sensor to be used on the trolley case and on a machine.
Portable unit
500 × 310 × 460 mm, 20 kg (dimension sequence as published)
Detector and optical mode
Peltier-cooled 256-pixel InGaAs, diffuse reflectance
Spectral range and resolution
950–1,800 nm, 6 nm optical resolution
Ingress protection and operating temperature
Unit IP33, sensor IP69K. Operating temperature −10 to +50 °C.
Connectivity
Wi-Fi, 4G and serial. Cloud functions use NIR Trace or NIR Evolution according to the enabled services.
Examples of machine installations
Forage harvesters, combines, balers, forage wagons, slurry tankers or feed mixers. Select an application pack suited to the machine type and model.
Fixed in-line installation
Dinamica Generale also documents the EvoNIR sensor in alfalfa dryers and grain elevators. The measurement point, integration and calibration are engineered for each line.
Calibration coverage
Material families and parameters are application-specific. Confirm the calibrations, software licences and accessories included in the quotation.

Technical documents and original sources

Application & use

With the correct kit, one EvoNIR sensor can move from the AgriNIR 4.0 trolley case to compatible machinery such as a forage harvester or feed mixer. Dinamica Generale calls this configuration NIReverse.

Use the portable case to test forage, silage, grain or slurry at the sampling point. For on-machine monitoring, specify the installation point, data integration and calibration for the material being measured.

For palm kernel meal or expeller (PKM/PKE), kernel, mesocarp or crude palm oil, specify the material and intended measurement. AE needs to check calibration availability and compare measurements with a reference method on samples from the mill before routine use.

Use in research

Choose equipment by application

Need help choosing an instrument or consumable?

Tell us about your sample or send the part number you already use.

Contact AE